Concert hall acoustics

Published: Jun 07, 20227 min read

As a special field of room acoustics, concert hall acoustic design focuses on spatial design for live musical events, usually without amplification. Concert halls are typically intended for classical music performances (mainly symphonic works) with an audience capacity ranging from 300 to 2500 seats. Some concepts already described in the article on room acoustics will be mentioned here.

Basic room shape

Only a few shapes serve as a starting point for concert hall design, and among these, the most typical trends are the shoebox (rectangular), fan-shaped, and vineyard styles.

Shoebox style

The shoebox shape is simply a rectangular room, usually featuring several balconies. As such, the basic design is simple, but if not carefully handled, this type of room can suffer from flutter echoes (as explained in our article on room acoustics). A famous example of a shoebox concert hall is the Musikverein in Vienna. It is generally agreed that various structures within this specific room, such as the side statues, provide scattering that helps avoid the flutter echo problem.

Fan style

Fan-shaped rooms are perhaps more common because they can accommodate a large number of attendees while still providing a direct line of sight to the performers. At the same time, they are less prone to flutter echoes simply because the walls are non-parallel. Additionally, the width of the room at the rear rows allows for a spacious sound. Although not specifically a concert hall, an example of a fan-shaped room is the auditorium at the Heydar Aliyev Cultural Center in Baku, Azerbaijan.

Concert hall acoustics
Auditorium in the Heydar Aliyev Cultural Center

Vineyard style

Vineyard concert halls are named as such because the seating areas resemble slopes in a vineyard. This type of room offers several advantages:

1) It is visually engaging.

2) The irregular pattern helps avoid acoustic issues such as flutter echoes and focusing (as explained in our article on room acoustics).

However, the disadvantage is that the design is very complex and expensive. Examples of famous vineyard concert halls include the DR Concert Hall in Copenhagen, Denmark, the Berlin Philharmonic Concert Hall in Berlin, Germany, and the Philharmonie de Paris in Amsterdam (just kidding – in Paris!), France.

Concert hall acoustics
DR Concert Hall

Suspended reflectors

An important objective of a concert hall is to deliver sound to different parts of the audience as evenly as possible. The actual ceiling of the room can hardly achieve this on its own. Therefore, suspended reflectors are often installed on the ceiling at angles that will reflect sound toward different audience areas.

Room acoustic parameters

Acoustic effects such as those described above can generally be measured objectively, and these measurable room acoustic parameters are specified in the ISO 3382-1 standard for performance spaces.

It is possible to determine optimal value ranges and the Just Noticeable Difference (JND). JND refers to the minimum increase in a parameter for the human ear to perceive it. That is, increments smaller than JND specified for a specific parameter are not expected to be noticeable.

Reverberation time (RT)

This parameter has already been described in our article on room sound insulation. Among the many types of RT listed in that article, the two most commonly used in concert halls are EDT and T30. Sometimes, T20 is preferred if the background noise level during measurement is too high to allow sufficient signal-to-noise ratio to generate T30.

Typical values for reverberation time in concert halls are 1.7 to 2.3 seconds.

Sound strength (G)

The G parameter investigates the degree to which sound/reflections contribute to the SPL level. In a highly reflective space/room, there will be a high contribution level, whereas in an absorptive space, there will be a low contribution level. In other words, G measures the room's gain relative to the sound source.

In short, G is measured by comparing the SPL from a sound source in the room with the SPL from the same source at a distance of 10 m in a free field. In practice, this procedure is not very convenient. Therefore, several methods have been developed based on the calibration of the measurement system. Read more about these procedures on the Application Notes page. Two similar parameters, Gearly and Glate, are used in auditorium acoustics to see the contribution of the room to the early and late SPL levels, respectively (sound arriving before and after 80 milliseconds from when the sound is emitted). It is also used in equations within the field of spatial impression of a room.

Typical G ranges for concert halls are 3 to 10 dB. Lower values are those measured farther from the source, while higher values are those measured closer to the source.

Clarity (C80) and Definition (D50)

Clearly, C80 compares the amount of sound energy arriving within the first 80 milliseconds to the total amount of energy until it ceases. Simply put, C80 compares early energy to late energy.

This parameter is based on the fact that room acoustic reflections later on have a greater blurring effect on sound than early acoustic reflections. Sound will be less clear when later reflections dominate the space over early reflections. Therefore, Clarity generally develops in the opposite direction of Reverberation Time (RT). A lower C80 is the result of a longer RT, while a higher C80 means a shorter RT. It should be noted that much acoustic research has been conducted for classical music, but not for rhythmic music (pop, rock, etc.). Therefore, these findings may not apply in the same way.

Typical ranges for C80 in concert halls are -1 to 3 dB.

Definition (D50) is very similar to Clarity, but focuses on the even earlier reflection part, up to 50 ms.

Lateral energy fraction (LF)

This parameter describes the spaciousness of the room, as previously described above. It is the ratio of energy arriving from all directions to the total (early) energy.

In a concert hall, this level is recommended to be greater than 0.25.

Early, late and total support (ST)

These parameters address stage support, as previously described above.

Early support (STearly) is calculated mainly using early reflections and describes ensemble conditions, i.e., the ease of hearing other members in the orchestra.

Late support (STlate) is calculated mainly using late reflections and describes the musicians' impression of reverberation.

Finally, total support (STtotal) is calculated using both early and late reflections, and represents the room's support for the musician's instrument.

The recommended values for early and total support are greater than -13 dB and -12 dB, respectively.

Below is a summary table of recommended values for the various parameters as described throughout this article. The recommended values are according to Gade (2003), and the subjective values are given by Bork (2000) and Bradley (1986).

Objective parameter Symbol Recommended
(Symphonic music)
Subj. limen
Reverberation time T30 1.7 – 2.3 seconds 5%
Clarity C80 -1 to 3 dB 1 dB
Level rel. 10m free field G > 3 dB 1 dB
Early Lateral Energy Fraction LF80 > 0.25 5%
Early Support STearly > -13 dB  
Total Support STlate > -12 dB  

References

Bork I, A Comparison of Room Simulation Software – The 2nd Round Robin on Room Acoustical Computer Simulation [Journal] // Acta Acustica 86. – 2000. – pp. 943-956.

Bradley J S, Predictors of speech intelligibility in rooms [Journal] // J. Acoust. Soc. Am. 80. – 1986. – pp. 837-845.

Gade A C, Room acoustic measurement techniques, Chapter 4 [Book Section] // Room acoustic engineering, Note 4213. – Lyngby, Denmark: Acoustic Technology, Technical University of Denmark, 2003.