It is recommended to use sound insulation and sound blocking with full-height masonry walls instead of stopping at the acoustical ceiling.
Before deciding to build floor-to-ceiling partition walls with suspended sound absorption ceilings instead of building them all the way up to the ceiling, consider whether you have thoroughly evaluated the situation, with the reason lying in limited budget? Or is it a truly correct decision that brings the highest efficiency to the project?
The impact of poor acoustic quality is significant.
Many building surveys conducted after occupancy show that people often complain about sound quality, specifically acoustic privacy. Poor acoustic quality frequently occurs in open-space buildings. At the same time, poorly designed private rooms also suffer from this condition.
We do not expect to have conversational privacy when being in a large and crowded area. However, when entering a private room and closing the door, you will pay attention to acoustic privacy/speech privacy. The issue is: whether that privacy is satisfied remains completely unknown. It depends on whether you build partition walls all the way up to the structural ceiling or just up to the suspended ceiling.
Before you do that, think about the weight of a wall compared to the weight of an acoustic ceiling tile. Consider how solid and heavy that wall is compared to a lightweight acoustic ceiling designed with many cutouts for installing lights and air conditioning equipment. The acoustic ceiling is unsuitable. That is why standards, guidelines, and building rating systems require walls to go all the way up to the structural ceiling with high Sound Transmission Class (STC) ratings (the higher this rating, the better the sound insulation).
What is sound insulation?
Sound insulation (also known as acoustic isolation) occurs when a large architectural surface or assembly with a non-porous, dense structure, such as a concrete floor/ceiling or multi-layer drywall, reflects sound energy.
Because sound reflects off the flat surface, very little sound is transmitted to adjacent rooms. Sound insulation helps provide acoustic privacy and speech privacy.
The acoustic design process is optimized by DASM through the use of floor-to-ceiling partition walls with good noise-blocking capabilities or lightweight partition walls on plenum ceilings combined with mineral wool sound-absorbing and sound-insulating ceilings to ensure privacy for conversations.

Overall sound insulation must address multiple noise sources above, below, and beside the rooms
as well as multiple paths through which noise can travel.
Sound insulation in building standards, guidelines, and rating systems
An increasing number of building types and room types must comply with stricter sound insulation criteria in building standards, guidelines, and rating systems.
The healthcare facility design and construction guidelines published by the Facility Guidelines Institute (FGI) require that "sound insulation must be considered for all construction projects with spatial and area division."
The WELL Building Standard applied to commercial office buildings states that "noise from surrounding spaces can be annoying to building occupants" and can negatively impact the human neuro-immune system.
The Collaborative for High Performance Schools (CHPS) emphasizes that "student learning suffers in poor acoustic environments," where "excessive noise negatively affects verbal communication" (EQ14.0). Minimum sound insulation performance must be achieved for all learning spaces.
How is sound insulation defined and measured?
The required sound insulation between rooms according to standards, guidelines, and building rating systems is determined in 1 of 2 ways – by the minimum Sound Transmission Class (STC) rating of the floor-to-ceiling wall or by the minimum Noise Isolation Class (NIC) rating of the entire architectural room enclosure after construction. Ceiling Attenuation Class (CAC) ratings are not recommended because they are associated with unacceptable design solutions.
Sound Transmission Class (STC)
STC is a laboratory-measured rating of the sound insulation performance of a wall assembly. STC ratings can also be used for doors, windows, and floor/ceiling systems. Higher ratings indicate better sound insulation between rooms. To determine the appropriate STC rating for a wall, consider the intended use of each room, the occupants' sensitivity to noise, and the amount of noise generated. Building standards, guidelines, and rating systems typically require STC ratings of 40, 45, or 50. Some more critical buildings require ratings above 50. If a wall has an STC rating requirement, that wall must extend from the floor all the way up to the structural ceiling, rather than just up to the suspended ceiling leaving an open gap. STC ratings are determined according to ASTM E90 standard.
Noise Isolation Class (NIC)
NIC is a field measurement of the total sound insulation performance between 2 rooms after construction is completed. Higher values indicate higher sound insulation between rooms. NIC accounts for all sound transmission paths such as through walls, doors, windows, and gaps through which sound can travel. NIC is used in some building standards, guidelines, and rating systems instead of STC because NIC accounts for all sound transmission paths and better reflects what people will experience in the space. NIC values of 35, 40, or 45 are typical in common applications. NIC ratings are determined according to ASTM E336 standard.
Ceiling Attenuation Class (CAC)
CAC represents the ability to block sound transmitting through the open space of a suspended ceiling when the wall is not built up to the structural deck. A high CAC value indicates a higher degree of sound insulation between rooms. Acoustic suspended ceilings typically have a CAC rating ranging from 20 to 35. In some cases, the CAC value can reach 40 or slightly higher. When lighting fixtures and supply and return air diffusers are installed, the CAC rating of the ceiling system drops by 10 points. CAC is not used in most building standards, guidelines, and rating systems because the acoustic suspended ceiling alone cannot provide the necessary sound insulation between rooms. CAC ratings are determined according to ASTM E1414 and ASTM E413 standards.
Understanding the practical sound insulation inside a building and how to block sound between rooms
The sound insulation capability between rooms on the same floor level is primarily related to walls and doors. In the past, some buildings typically designed partition walls that did not go all the way to the structural ceiling but stopped at the suspended ceiling, leaving an open space above the ceiling. Designers did not realize that if walls were built only up to the sound-absorbing ceiling, the sound insulation between rooms would not be high. They did not know that the sound insulation of the ceiling (CAC value in the range of 20-35) must match the sound insulation of the wall (STC around 40, 45, or 50). In reality, ceiling systems usually have a sound insulation performance 10-20 points lower than wall systems.
Although most current building standards, guidelines, and rating systems do not recognize this type of wall, we can still see it appear in some older buildings as well as newly constructed ones.
Building walls only up to the suspended ceiling and relying solely on that suspended ceiling for sound insulation is a risky and discouraged design method. This design solution is still used because some ceiling manufacturers still claim that an acoustic ceiling alone is enough to block noise or sound between rooms. When choosing to buy a suitable ceiling type, you may find that products on the market are advertised as having both sound absorption and sound blocking capabilities. In reality, modular acoustic ceilings cannot block noise because their mass is not large.
Additionally, when sound-reducing ceiling panels are installed in a standard suspension grid/framework, along with other building system components such as air diffusers (left), lighting fixtures (middle), and return air grilles (right), critical boundary sound paths - or noise leaks - are created. Acoustic experts use a high-resolution acoustic camera equipped with a sound intensity probe to help designers see the noise leaking through the ceiling system (red and yellow). These noise leaks significantly reduce the acoustic performance of the ceiling system. In fact, they can cut the sound-blocking performance in half, allowing sound to travel freely between adjacent rooms.

A high-resolution acoustic camera shows sound leaking through the ceiling system
If you are looking for a solution that both blocks and absorbs sound, dual-action panels currently on the market are truly the ideal solution meeting both requirements. Designers have inadvertently traded Noise Reduction Coefficient (NRC) for Ceiling Attenuation Class (CAC) ratings, and thus the sound insulation or sound-blocking capability of the ceiling is not high. Pay attention to suspended ceiling panels to meet high sound absorption requirements and focus on walls to block noise if needed. The CAC solution currently does not comply with most acoustic standards, guidelines, and rating systems.
How to optimize sound insulation between rooms?
DASM's acoustic optimization solutions comply with building standards, guidelines, and rating systems in cases where walls are built up to the structural deck and rated for STC to block noise between rooms. Building walls only below the suspended ceiling and leaving the space above open will facilitate sound transmission between rooms. This design method is not permitted, and no effective noise-blocking solution can fix this design flaw.
Plenum ceiling
Plenum ceiling design is increasingly encouraged by many standards, guidelines, and rating systems, prompting designers to use lightweight plenum barriers to block sound transmission through this plenum space when room partitions only reach the suspended ceiling. This is a necessary requirement because the acoustic properties of the ceiling are not sufficient to guarantee speech privacy. The combination of an acoustic ceiling and a noise-blocking barrier above the plenum ceiling aligns with the STC performance of the partition below the acoustic ceiling.
The noise-blocking barrier above the plenum ceiling is an excellent sound-blocking solution, starting from the top of the partition below the acoustic ceiling all the way up to the underside of the floor or roof above.

There are 2 options to optimize sound insulation between rooms: high walls or full-height partitions.
Avoid leaving an open plenum cavity because it does not comply with acoustic standards
How to choose the appropriate Sound Transmission Class (STC) rating
DASM's acoustic experts will help you choose the appropriate STC rating. First, the level of human- and equipment-generated noise audible from the neighboring room will be determined. Next, consideration will be given to what people will do in that space, their sensitivity to that annoying noise, and the level of privacy they require.
Sound insulation between rooms with an STC rating of 50 or higher is considered the best, 45 is very good, and 40 is good. Avoid STC acoustic ratings below 40 as they do not provide the necessary acoustic privacy. Designers can achieve all 3 of these performance categories by using a full-height wall extending up to the structural deck or combining an acoustic ceiling with other effective sound insulation products to insulate the plenum ceiling section.
If an adjacent room contains many people or equipment and the transmission of noise would disrupt the activities being performed in the design room, use an STC rating of 50 as the best option. For example: in classrooms, an STC rating of 50 is also used for spaces requiring high levels of confidentiality, such as in executive offices.
If a room is only occasionally occupied and the main function of the design room is not acoustically sensitive, use a higher STC value, approximately 45. Some examples of facilities where an STC rating of 45 should be applied are standard offices, private offices, and patient rooms in healthcare facilities.

Sound insulation ratings include: Best – STC 50. Better – STC 45. Good – STC 40. Avoid STC below 40
Understand the difference: Why does a plenum barrier combined with an acoustic ceiling perform better than just an acoustic ceiling?
Acoustic experts have used a high-resolution acoustic camera linked to a sound intensity probe to clearly see the difference between using only an acoustic ceiling to provide sound insulation between rooms and enhancing the performance of the suspended ceiling by installing additional plenum barriers. This visualization method clearly shows noise passing through the mineral wool acoustic ceiling with a high CAC rating (CAC 37) in red and yellow colors. The areas with the most noise transmission are at the return air grille on the right and the recessed light fixture area in the center. Other noise transmission paths include the supply air diffuser on the left and at the intersections of the wall and ceiling. Overall, these sound leaks reduce the ceiling system CAC rating to only 27, a reduction of 10 CAC points.
When using mineral wool acoustic suspended ceiling panels and plenum barriers (image below), the phenomenon of noise leakage disappears. DASM’s acoustic optimization solution operates at STC/CAC values of 40, 45, or 50 (in the image is STC/CAC 50) depending on the combination of the suspended ceiling and the plenum barrier. When combined, the noise level is low, represented by purple, and is more than 25 decibels lower than when only mineral wool suspended ceiling panels (top image) are used for ceiling sound insulation.

Visualize noise leakage through the ceiling and blocking with a plenum barrier
When should you choose a plenum barrier instead of building full-height walls up to the underside of the floor deck?
From an acoustic perspective, full-height walls are the preferred design solution in most cases. If building design must comply with STC ratings in standard systems, guidelines, or rating systems, full-height walls should be built. An increasing number of standards, guidelines, and rating systems allow designers the option of using lightweight plenum barriers combined with acoustic ceilings or building full-height walls. Of these two solutions, the use of lightweight plenum barriers should be considered for cost-effectiveness, taking into account the simplicity of construction and installation.
In some designs, full-height walls are not an optimal choice. The widespread use of modular, prefabricated wall systems is a prime example. These types of walls are often installed below a suspended ceiling. None of these offer wall partitions designed to be full-height. Instead of creating an additional plasterboard barrier above these prefabricated walls or leaving the space above the suspended ceiling open, DASM experts demonstrate that a lightweight plasterboard plenum barrier is the optimal design solution. Similarly, when a raised floor is installed, creating a large void beneath the floor, we should also install a barrier for that space beneath to maintain the sound insulation capability of the wall above.
The construction and interior finishing processes of many buildings erected in the 1980s and 1990s made the mistake of only building partitions up to the suspended acoustic ceiling and relying on CAC 35-rated suspended ceilings to block noise. Today, we are still dealing with the sound insulation issues of those buildings. As our knowledge of acoustics increases, requirements for noise control also rise, and more people are complaining about the lack of acoustic privacy. This is another excellent application for plenum barriers above the ceiling. It is simply too difficult to rebuild or impossible to extend plasterboard walls to full height.
Lan Huong/ DASM
VILAS 1541 · ISO/IEC 17025
Need advice on SOUND DESIGN & SIMULATION SERVICES?
Acoustical design services, sound simulation using software for projects specializing in acoustics
Related Articles
Articles from the same category or related topics
- 6 min read
From Vietnamese Acoustic Knowledge to International Forums: DASM's Research Milestone in Acoustics Australia
A research paper on acoustic materials by DASM was published in Acoustics Australia, a world-renowned acoustic journal, marking a new step forward for DASM in the field of acoustics
Read more → - 3 min read
DASM Sound Absorption Testing for Noise Barriers According to ISO 354:2024 & EN ISO 11654:1997
DASM sound absorption testing for Noise Barriers in a reverberation room according to ISO 354:2024 and EN ISO 11654:1997 standards at a VILAS-certified laboratory