Test method for determining room acoustic parameters for ordinary rooms
The test method Determination of room acoustic parameters for ordinary rooms helps calibrate other acoustic measurements; compare and calculate effective acoustic design for rooms for ordinary rooms...
Overview of the test method Determination of room acoustic parameters for ordinary rooms
Test method name: Acoustics – Measurement of room acoustic parameters – Part 2: Reverberation time in ordinary rooms.
Test method:
ISO 3382-2:2009: Acoustics – Measurement of room acoustic parameters – Part 2: Reverberation time in ordinary rooms [1]
Carried out at: Field conditions of ordinary rooms.
Objectives and test objects
– Objective
This standard specifies the methods for measuring reverberation time in ordinary rooms. It describes the measuring procedure, necessary equipment, required number of measurement positions, and the method for evaluating data and presenting the test report. The results can be used to calibrate other acoustic measurements, for example, sound pressure levels from sound sources or sound insulation measurements, and to compare with reverberation time requirements in rooms.
– Object:
Performance spaces, auditoriums.
– Notes on averaging measurements
The number of microphone positions used shall be determined according to the required accuracy. However, due to the inherent stochastic nature of the source signal, it is necessary to average over a number of measurements at each position to obtain an acceptable measurement uncertainty (see 7.1). Averaging at each position can be done in two ways:
- Determine separate reverberation times for all decay curves and average the values.
- Or average the set of squared sound pressure decays and determine the reverberation time of the resulting decay curve. The individual decays are superimposed with synchronized starting points. The individual squared sound pressure values of the sample are summed for each single sample with each increment of time interval of the decays, and the sequence of these sums is used as the single overall decay from which T is evaluated (see Reference [20]). The acoustic power emitted by the source must be kept the same for all measurements. This is the preferred method.
Experimental procedure
Steps to perform:
- Fully prepare equipment, microphones, and test samples.
- Determine measurement positions.
- Perform sample testing:
+ Interrupted noise method
+ Impulse response integration method
- Process and report results.

Role – and importance of the test method Determination of room acoustic parameters for ordinary rooms
The test method Determination of room acoustic parameters for ordinary rooms conducted by the Institute for Development & Application of Acoustic Materials helps meet all practical needs:
- Enterprises need to control quality during production, optimize research and development of products and services to meet high performance for the acoustic environment of ordinary rooms.
- Customers need to obtain certificates and test results to enhance the value and brand of constructions and projects... in a convenient, transparent, and compliant manner.
- Have a basis and standards to evaluate room acoustic parameters; compare and calculate effective acoustic design.
In addition, in cases where the object does not meet the standards, DASM will proceed with consulting and designing solutions regarding shapes, layouts, structures, and materials used to calibrate the design in a streamlined, effective, and cost-saving manner.
If previously you had some concerns and worries and had to spend many expenses on similar activities abroad, now you just need to contact DASM. The entire remaining process will be proactively carried out by us as a complete package in the shortest time to improve customer experience with us: DASM provides acoustic consulting services with truly superior quality, the most competitive prices in the industry along with attentive and dedicated customer care policies.
Significance of acoustic testing services at DASM
Today's globalized commercial life opens up countless new markets and sources of supply across five continents. Accompanied by international regulations and standards, it helps customers easily assess quality, trace product origins, and select suitable/superior items. In particular, they also support manufacturers to continuously improve and perfect technology, techniques, raw materials, production methods, sales, etc.
The Institute for Development & Application of Acoustic Materials (DASM) is a pioneering, comprehensive, professional, and leading reputable brand in Vietnam in the field of acoustics. On January 12, 2023, DASM was granted certificate No. 114/TĐC – HCHQ by the Directorate for Standards, Metrology and Quality (Ministry of Science and Technology), certifying registered testing activities for a multi-industry combination in the Mechanical-Physical field (registration number: 707/TN – TĐC).
Our acoustic testing services provide customers with practical professional results to meet sustainability, standard performance, and optimal design solutions – consulting – calibration for products and services. From there, you will update, meet, and adapt to constantly changing international standards to achieve breakthroughs in revenue, profit, and elevate your brand.
If you have a need to perform the test method Determination of room acoustic parameters for ordinary rooms, please contact us via Hotline for detailed consultation!
VILAS 1541 · ISO/IEC 17025
Need advice on Materials Acoustic Testing?
Services of testing, measuring and analyzing acoustic properties of equipment, products, vehicles, acoustic materials, etc.
Related Articles
Articles from the same category or related topics
- 3 min read
DASM Sound Absorption Testing for Noise Barriers According to ISO 354:2024 & EN ISO 11654:1997
DASM sound absorption testing for Noise Barriers in a reverberation room according to ISO 354:2024 and EN ISO 11654:1997 standards at a VILAS-certified laboratory
Read more → - 7 min read
DASM Institute surveyed the acoustics of the recording booth at the Ministry of Public Security according to ISO 3382 standard
DASM Institute conducted an acoustic survey and noise testing in the recording booth at the Ministry of Public Security, including SNR measurement and acoustic characteristic evaluation according to ISO 3382 standard.
Read more → - 3 min read
Advanced Acoustic Measurement & Noise Emission Testing for International Testing & Certification Laboratories
DASM provides advanced acoustic measurement and noise emission testing services for Testing & Certification laboratories, ISO-compliant procedures
Read more →