ISO 11546-1:1995 – Acoustics — Determination of sound insulation performances of enclosures — Part 1: Measurements under laboratory conditions (for declaration purposes)

1 Scope This part of ISO 11546 specifies laboratory methods for the determination of the sound insulation performance (insertion loss) of small machine enclosures. It applies to a total enclosure only and not to the individual panels from which the enclosure is made. NOTES 1 Sound insulation for enclosure panels such as wall elements, doors, […]
ISO 11546-1:1995 – Acoustics — Determination of sound insulation performances of enclosures — Part 1: Measurements under laboratory conditions (for declaration purposes)

1. Scope This part of ISO 11546 specifies laboratory methods for the determination of the sound insulation performance (insertion loss) of small machine enclosures. It applies to a total enclosure only and not to the individual panels from which the enclosure is made. NOTES 1 Sound insulation for enclosure panels such as wall elements, doors, […]
TCVN 7839 – 1 : 2007 – Âm học – xác định hiệu quả cách âm của vỏ cách âm – phần 1: phép đo ở điều kiện phòng thí nghiệm (để công bố kết quả)

Tiêu chuẩn này quy định các phương pháp trong phòng thí nghiệm để xác định hiệu quả cách âm (độ suy giảm âm) của vỏ cách âm đối với các máy nhỏ. Tiêu chuẩn này không áp dụng cho từng phần cấu tạo nên vỏ cách âm mà chỉ áp dụng cho toàn bộ vỏ […]
ASTM E1014-12(2021) – Standard Guide for Measurement of Outdoor A-Weighted Sound Levels

Significance and Use 4.1 There are numerous situations for which outdoor sound level data are required. These include, but are not limited to, the following: 4.1.1 Documentation of sound levels before the introduction of a new sound source (for example, assessment of the impact due to a proposed use). 4.1.2 Comparison of sound levels with […]
ISO 1996-2:2017 – Acoustics — Description, measurement and assessment of environmental noise — Part 2: Determination of sound pressure levels

Introduction Measurements of environmental noise are complicated because there is a great number of variables to consider when planning and performing the measurements. As each measurement occasion is subject to current source and meteorological conditions which cannot be controlled by the operator, it is often not possible to control the resulting uncertainty of the measurements. […]
TCVN 7878-2:2018 – Âm học – mô tả, đo và đánh giá tiếng ồn môi trường – phần 2: xác định mức tiếng ồn môi trường

1. Phạm vi áp dụng Tiêu chuẩn này mô tả cách xác định mức áp suất âm bằng phép đo trực tiếp, bằng phép ngoại suy các kết quả đo từ các phép tính trung bình, hoặc bằng cách loại trừ, để làm cơ sở cho việc đánh giá tiếng ồn môi trường. Các khuyến […]
ISO 9612:2009 – Acoustics — Determination of occupational noise exposure — Engineering method

Introduction This International Standard provides a stepwise approach to the determination of occupational noise exposure from noise level measurements. The procedure contains the following major steps: work analysis, selection of measurement strategy, measurements, error handling and uncertainty evaluations, calculations, and presentation of results. This International Standard specifies three different measurement strategies: task-based measurement; job-based measurement; […]
TCVN 9799:2013 – Âm học – Xác định mức tiếp xúc tiếng ồn nghề nghiệp – phương pháp kỹ thuật

1. Phạm vi áp dụng Tiêu chuẩn này quy định phương pháp kỹ thuật đo đối với sự tiếp xúc với tiếng ồn của người lao động trong môi trường làm việc và tính mức tiếp xúc tiếng ồn. Tiêu chuẩn này đề cập đến các mức âm trọng số A nhưng cũng có thể […]
ASTM E1222-90(2016) – Standard Test Method for Laboratory Measurement of the Insertion Loss of Pipe Lagging Systems

Significance and Use 5.1 The insertion loss of a pipe lagging system depends upon the lagging system materials, the method used to apply the materials, the pipe wall thickness, the size and shape of the bare and lagged pipe, and the mechanisms causing noise radiation from the pipe. Insertion losses measured using this test method […]
ISO 7235:2003 – Acoustics — Laboratory measurement procedures for ducted silencers and air-terminal units — Insertion loss, flow noise and total pressure loss

Introduction This International Standard specifies the substitution method for determining the insertion loss of ducted silencers and a method for determining the transmission loss of air-terminal units. In the substitution method, the sound pressure level of the transmitted wave is first determined for the test object and then when the test object has been replaced […]